三叶罗茨风机烧毁的原因及解决方法

文章来源: 作者:罗茨机电 发布时间:2022-03-30 浏览次数:1220

返回: 新闻中心

三叶罗茨风机烧毁的原因及解决方法

Causes and solutions of burning of three blade roots blower

一、管道,管道的压力是一个容易导致风扇温度过高的因素,三叶罗茨风机根据不同口径在出风口有固定数量的主管,如果人为改变有特殊要求的管道口径,容易造成压力减小,在养殖方面,主管往往比较细,如果修改主管道口径,需要采取相应措施,保证风机压力正常。

1、 The pressure of the pipe is a factor that easily leads to the excessive temperature of the fan. The three blade roots fan has a fixed number of main pipes at the air outlet according to different diameters. If the pipe diameter with special requirements is artificially changed, it is easy to reduce the pressure. In terms of breeding, the main pipes are relatively thin. If the diameter of the main pipe is modified, corresponding measures need to be taken to ensure the normal pressure of the fan.

二、工作环境,按照正常的设计标准,风机应该在风机泵房内运行,但根据笔者多年的经验,大多数三叶罗茨风机都是露天运行的,夏季因素的影响更加明显,如果条件允许,现场可配备制冷降温设备,尽可能避免环境因素对风机的影响,或配备隔音罩,配备散热装置。

2、 Working environment: according to the normal design standard, the fan should operate in the fan pump room. However, according to the author's many years of experience, most three leaf roots fans operate in the open air, and the influence of summer factors is more obvious. If conditions permit, refrigeration and cooling equipment can be equipped on site to avoid the influence of environmental factors on the fan as far as possible, or sound insulation cover and heat dissipation device can be equipped.

3b50fa049ef867042e757c5529eae7f9 [更大
宽度 640 更大
高度 480].jpg

三、风扇的配置,风扇的压力随着风量的变化是恒定的,但是经常会有小马拉车的情况,也就是小电机带大风扇,这样,为了满足使用流量要求,风扇会对电机造成比较大的负荷,从而导致电机烧坏,风扇烧坏。

3、 The configuration of the fan and the pressure of the fan are constant with the change of the air volume, but there are often cases of a pony pulling a cart, that is, a small motor with a large fan. In this way, in order to meet the flow requirements, the fan will cause a relatively large load on the motor, resulting in the motor burning out and the fan burning out.

四、安装风扇,如果刚开始新风扇的流量压力没有问题,没有过载或者发热,但是过一段时间就会开始燃烧,说明风扇需要重新检查皮带的松紧度,重新拧紧固定螺丝。

4、 Install the fan. If there is no problem with the flow pressure, overload or heating of the new fan at the beginning, but it will start to burn after a period of time, it indicates that the fan needs to recheck the tightness of the belt and retighten the fixing screws.

三叶罗茨风机操作规程

Operating procedures for three blade roots blower

一、三叶罗茨风机开机前的准备和检查

1、 Preparation and inspection of three blade roots blower before startup

电压波动值在380V10%范围内,三相电源不能异相;仪表和电气设备应完好,需接地的电气设备应可靠接地;风机与管道的连接,框架螺栓等,应紧固;齿轮箱中的润滑油应按照指定的品牌进行标记,并添加到机油标记线上;启动前用手转动滑轮2~3次,看有无异常;风机出口阀关闭,放空阀全开。

The voltage fluctuation value is within 380v10%, and the three-phase power supply cannot be out of phase; Instruments and electrical equipment shall be intact, and electrical equipment to be grounded shall be reliably grounded; The connection between fan and pipeline, frame bolts, etc. shall be fastened; The lubricating oil in the gearbox shall be marked according to the specified brand and added to the oil marking line; Before starting, rotate the pulley by hand for 2 ~ 3 times to see if there is any abnormality; The outlet valve of the fan is closed and the vent valve is fully opened.

二、三叶罗茨风机开始运行

2、 Three blade roots blower starts operation

打开三叶罗茨风机排气阀和排气阀;启动电源,30秒后,如无异常现象(如金属摩擦、电流过大等),逐渐关闭排气阀,使其正常运行;正常运行时,切勿关闭出口阀,以免发生爆裂事故;如果同时打开几个风扇,应该先打开一个,空载运行正常后再打开另一个,空载运行正常后(30秒),关闭排气阀。

Open the exhaust valve and exhaust valve of three blade roots blower; Start the power supply. After 30 seconds, if there is no abnormal phenomenon (such as metal friction, excessive current, etc.), gradually close the exhaust valve to make it operate normally; During normal operation, do not close the outlet valve to avoid bursting accident; If several fans are turned on at the same time, one should be turned on first, and then the other should be turned on after the no-load operation is normal. After the no-load operation is normal (30 seconds), close the exhaust valve.

三、关机操作

3、 Shutdown operation

停机前做好记录,记下电压、电流、风压、温度、运行时间等数据,逐步打开排气阀;按下停止按钮;关闭排气阀。

Make records before shutdown, record the voltage, current, wind pressure, temperature, operation time and other data, and gradually open the exhaust valve; Press the stop button; Close the exhaust valve.

四、风扇的巡视

4、 Inspection of fan

风机正常运行后,每小时巡视一次,记录仪表读数(电压、电流、风压、温度等)每2~3小时一次,巡视时,注意风扇声音是否正常,运转时不应有摩擦声和撞击声,如有异常,立即停机检查。

After the fan operates normally, patrol inspection shall be conducted once every hour, and the instrument readings (voltage, current, wind pressure, temperature, etc.) shall be recorded once every 2 ~ 3 hours. During patrol inspection, pay attention to whether the fan sound is normal, and there shall be no friction sound and impact sound during operation. If there is any abnormality, stop the machine immediately for inspection.